- New

Product No.: 20002233
Solid State Relay for 12V Direct Current with DIN Socket,and 1 contact set for 230VAC
Load circuit: 1-phase 12 ... 275 VAC / 25 A or 24 ... 600 VAC / 35 A
Switch switch: 1 NO switch (triac, zero voltage switch)
Nominal steering voltage: 160 ... 240 V AC / DC
Rated coupling voltage: 12 ... 275 V AC
Continuous current: 17 A (AC51) at 40°C, 3.5 A (AC 53)
Connection via screw terminals, clamps for steering voltage can be loosened
Dimensions (BxHxD): 22.5x90.5x115.4 mm
kr400.00 tax excl.
Relay to 12V - remember to use a diode (e.g. 1N4001-7) over the coil (the line against the plus).
The relay has a consumption of 130 mA. The contact kit can be loaded with a maximum of 10 amps at 230 volts of alternating current.
The relay has two contact sets NO/C/NC
Reference : 20002224
4 relays in print, transistor controlled. Low activation consumption. Minus and plus activation, relay 12V 10A.
Reference : 20002220
12VDC 30A relay in print, transistor controlled with optocoup connection and a contact set (NC-C-NO). Low activation consumption. + & activation.
Reference : 20002221
A print relay, 12V 10A, transistor control with optocoupler, a contact kit, low activation consumption. +/- activation.
Reference : 20002227
Relay to 12V DIRECT CURRENT with DIN socket,and 1 contact set for 230VAC 16A.
Coil voltage: 12 V (starting voltage 8.4 V-)
Coil resistance: 360 ohm
Shift switch: 1 switch switch
Contact rating: 16 A / 250 V ~
Operating temperature: -40 ... + 85 ° C
Contact material: AgNi 90/10 gilt
Dimensions (LxBxH): 29x12.7x15.7 mm
Reference : 20002234
A print relay, 24V 5A, transistor controlled with optocoupler, a contact set, low activation consumption. +/- activation.
Reference : 20002228
8 relays in print, transistor controlled. Low activation consumption. Minus activation, relay 12V 10A.
Reference : 20002222
2 relays in print, transistor controlled. Low activation consumption. Minus activated, relay 12V 10A ( first edition )
Model with Vref you can choose whether the relays should be activated with a positive or negative.
For example, if you want a positive activation, Vref must be mounted tol minus. Then you can activate the relays with a plus of CH1 or CH2
Solid State Relay for 12V Direct Current with DIN Socket,and 1 contact set for 230VAC
Load circuit: 1-phase 12 ... 275 VAC / 25 A or 24 ... 600 VAC / 35 A
Switch switch: 1 NO switch (triac, zero voltage switch)
Nominal steering voltage: 160 ... 240 V AC / DC
Rated coupling voltage: 12 ... 275 V AC
Continuous current: 17 A (AC51) at 40°C, 3.5 A (AC 53)
Connection via screw terminals, clamps for steering voltage can be loosened
Dimensions (BxHxD): 22.5x90.5x115.4 mm